Verified Knowledge Base · 60 Q&As

RoomBanker Frequently Asked Questions

Filter by hardware category or keyword—every answer matches official RoomBanker 868 MHz RBF specifications.

How many wireless devices can connect to the R2 PRO hub?

Per official RoomBanker specifications, the hub manages up to 128 wireless peripherals across up to 64 rooms using RBF 868 MHz and Bluetooth protocols.

How does it keep working during internet or power outages?

It combines Ethernet, Wi-Fi, and 4G cellular backup alongside a built-in backup battery to keep alarm transmission uninterrupted.

How are peripherals paired with the hub?

Open the hub in the RB Link app, tap "+" and select "Add peripheral", then power on the sensor for auto-enrolling or scan its QR code.

How do I pair the RBGW-RE1-868 repeater with the hub?

Tap "+" → "Add peripheral" in the RB Link app and power on the repeater for auto-enrolling. If the green LED stays off, press and hold the register button for 5 seconds.

How do I verify signal strength at the mounting spot?

Run "Signal Strength Test" in RB Link: Green indicates strong reception, Orange means medium, and Red signals weak reception.

Does the repeater stay online during a power outage?

Yes, the unit includes an internal backup battery and also supports the "Find me" green LED locator.

Does RBSS-PS1-868 support pet immunity?

Yes, the official datasheet specifies pet immunity up to 10 kg alongside digital temperature compensation.

How do I verify detection after mounting the PIR sensor?

Per the Quick Start Guide, start "Installation test" in RB Link and walk across the room—the LED flashes RED when motion is detected properly.

How do I power on and mount the sensor?

Pull out the battery insulation strip for auto-pairing (or hold the register button for 5 seconds). Mount using wall bracket A, bracket B, or the 3M strip.

What is the detection range and pet immunity of RBSS-PS2-868?

The official specification lists a 16 m detection range, 90° angle, and pet immunity up to 35 kg.

What do the Signal Strength Test LED colors indicate?

Per the Quick Start Guide (auto-off after 2 min): Green (3s on/off) = Strong, Orange = Medium, Red = Weak, fast Red flash = Lost. Motion triggers a red flash every 500 ms.

How is it paired with the RoomBanker hub?

In RB Link select "+" → "Add peripheral" and pull the battery insulation strip for auto-enrolling (or hold the register button for 5s if the green LED stays off).

What separation gap triggers the RBSS-MC1-868 sensor?

The official specification lists a reed switch detection gap of > 17 mm.

How is the sensor mounted and protected against removal?

Per the Quick Start Guide, mount it on the door or window using the 3M adhesive strip; a rear tamper switch detects forced removal.

How can I identify one specific door sensor in a large building?

Enable "Find me" in the RB Link app so the target sensor flashes green.

How does Door Window Sensor G2 differ from MC1?

G2 includes 2 reed switches, a magnetometer that detects magnet spoofing, and an accelerometer for tilt and shock detection.

How are tilt and shock alerts configured?

Per the datasheet, tilt threshold is configurable from 5° to 25° and shock has 3 sensitivity levels (Low/Normal/High), while ignoring brief vibrations up to 0.15 s.

Can RBSS-MC2-868 accept a wired external sensor?

Yes, it supports an external wired contact (NC/NO) and roller shutter monitoring.

What measurement range and accuracy does RBSS-TH1-868 deliver?

The official specification rates temperature from -10 °C to +55 °C (±0.5 °C accuracy) and humidity from 0 to 99% RH (±5% accuracy).

Can it switch between Celsius and Fahrenheit?

Yes, unit switching between Centigrade and Fahrenheit is supported and configurable via the RB Link app.

How is it paired to the hub?

Remove the back shell and insert the battery—the signal bar lights up sequentially for automatic pairing (or hold the register button for 5 seconds).

How does RBSS-WL1-868 detect leaks and is it waterproof?

It is IP66 rated and detects water via both the main body bottom contacts and an extension cable for high-precision multi-point monitoring.

Where should the water leak detector be placed?

Recommended for leak-prone zones such as kitchens, bathrooms, balconies, and under sinks, boilers, or washing machines.

How do I activate and pair it in RB Link?

Remove the back shell and install the battery—the green LED flashes for automatic pairing (or hold the register button for 5s if needed).

What sensing element and alert types does RBSS-SM1-868 use?

The official specification uses a photoelectric smoke sensor paired with both sound and voice notifications.

How is the smoke detector mounted on the ceiling?

Per the Quick Start Guide, mount it on the ceiling either with screws or with the included 3M adhesive strip.

How do I add it to the RB Link hub?

Select "+" → "Add peripheral", power on the detector, then press the button until the green indicator turns on and release for automatic pairing.

Are siren volume and duration adjustable on RBAD-SI1-868?

Yes, the datasheet specifies 85 dB / 95 dB / 105 dB sound levels and configurable alarm duration from 1 second to 15 minutes (90 seconds default).

How is it powered and protected against tampering?

It runs via the supplied EU power cable with backup battery support and features rear tamper protection.

How do I test the siren after adding it in RB Link?

Both Volume Test and Signal Strength Test can be triggered remotely inside the RB Link app.

Does the RBAD-SO1-868 (Blue) siren need external AC wiring?

No, it includes a built-in solar panel for battery charging and connects wirelessly over 868 MHz RBF.

What are the volume levels and weather rating?

Volume is adjustable between 85 dB, 95 dB, and 105 dB, alarm duration from 1s to 15 minutes (90s default), and the housing is IP65 rated with rear tamper.

How do I add the outdoor siren in RB Link?

Tap "+" → "Add peripheral", flip the power switch on the siren so the indicator flashes, and assign a room (or hold the register button 5s if needed).

What is the difference between Red and Blue RBAD-SO1 models?

Both share identical IP65 weatherproofing, solar panel charging, and 85/95/105 dB output; they differ only in strobe lens color (Red vs. Blue).

Is the siren protected against removal from the wall?

Yes, rear tamper protection immediately triggers an alert if the housing is pried from the facade.

Can alarm duration be customized?

Yes, duration is adjustable from 1 second to 15 minutes (90 seconds by default) via RB Link.

What optical and night vision specs does RBVD-IC1-M4 have?

It provides 4MP resolution, a 3.6mm lens with 85° horizontal field of view, F2.0 aperture, digital WDR, and infrared night vision up to 10 meters.

Does it support local storage, tracking, and privacy mode?

Yes: MicroSD/TF cards up to 256 GB, horizontal pan & vertical tilt, auto human tracking, half-duplex intercom, and Privacy Protection mode.

How is the camera set up?

Open RB Link, power on the camera with the EU adapter, and scan the QR code to register in 3 steps.

What is the battery runtime of RBVD-OC1-M5?

Its 9600 mAh lithium battery delivers up to 6 months standby or 1.5–3 months of active use per charge, and supports optional solar panel charging.

What camera optics and PIR specs are included?

5MP (2.5K) resolution, 3.6mm 120° wide-angle lens, F1.8 (0.01 Lux), 10m IR night vision, WDR, and an aligned 10m / 120° PIR human sensor.

Is it weatherproof and equipped with audio?

Yes, it is IP65 dust/water resistant and features a built-in speaker to broadcast remote voice warnings via RB Link.

What buttons and controls are on the RBCT-KP1-868 keypad?

The official spec lists 15 buttons: 0–9, Clear, Arm Away, Arm Stay, Disarm, and a Custom Button.

Does it support duress alarm and tamper detection?

Yes, it supports silent duress alarms alongside rear tamper protection.

How do I pair the keypad with the hub?

Select "+" → "Add peripheral" in RB Link and switch on the keypad so the green LED flashes (hold the register button 5s if needed).

What functions do the 4 buttons on RBCT-KF1-868 perform?

It provides dedicated Arm and Disarm buttons plus 2 Custom Buttons whose actions are configured inside RB Link, with green LED confirmation.

Can a keyfob be assigned to a specific user?

Yes, the Quick Start Guide includes the "Associate User" step right after adding the keyfob to assign ownership.

How do I pair the keyfob if the green LED stays off?

Pull out the battery insulation strip; if the green LED does not flash, press and hold the "+" button for 5 seconds.

What power supply and load does RBAD-RL1-868 support?

The specification describes it as a dry-contact relay controlling 6–36V⎓ circuits, wired to a 7–24V DC power supply per the Quick Start Guide.

What Smart Scene triggers are available?

RB Link supports scenes triggered By Alarm, By Operation, By Fault, and By Schedule, plus local physical button switching.

How do I pair and test signal strength?

Connect 7–24V DC power while adding a peripheral in RB Link (hold power button 5s if the green LED stays off), then run Signal Strength Test or Find me.

What wall box and voltage does RBAD-WS1-868 support?

It fits a standard 86 electrical box and connects to a 110V or 230V AC supply using the supplied terminal block.

Does it provide energy monitoring?

Yes, the official spec confirms monitoring for current, voltage, and power consumption alongside RB Link Smart Scenes.

How is the wall switch paired with the hub?

After wiring 110/230V AC power, open the hub in RB Link, tap "+", and scan the device QR code.

Which wired devices work with RBAD-TR1-868?

It integrates any third-party detector, keypad, or panic button with NC or NO contact types into the RoomBanker RBF system.

Can the transmitter power the attached wired sensor?

Yes, the specification states it can output 3.3 V / 30 mA power and NC/NO signals to a third-party device.

How is it powered and located with Find me?

Insert 3 batteries to auto-pair (or hold the register button 5s). Activating "Find me" flashes the green indicator (1s on / 1s off) for 30 seconds.

How does Child Lock work on RBAD-PL1-868 (EU)?

When Child Lock is enabled in RB Link, the physical button on the plug is locked so the outlet cannot be toggled locally.

Does the smart plug track energy usage?

Yes, the official datasheet specifies power consumption monitoring alongside remote ON/OFF and Signal Strength Test.

How do I pair the EU smart plug?

Tap "+" → "Add peripheral" in RB Link and plug it into a 230V outlet—the blue LED flashes for auto-enrolling (or hold the power button 5s).

Consultation & System Sizing

Design a RoomBanker Setup Tailored to Your Property

Share your property layout and security goals—our Riga engineering team will recommend the right 868 MHz sensor kit and guide you to order on our main website.

SIA "Apsardze 24"

VAT / Tax ID LV40003889451

Latgales 293-5, Riga, LV-1063, Latvia